Worldwide:
920-133 Exam
Home >> Nortel >> NCSS >> 920-133

920-133, Nortel 920-133 Exam

Nortel 920-133 test
  • Questions and Answers
  • 62 questions
  • Update time
  • February 20th,2010
  • Software Price
  • $159.99 $109.99

loading loading

Product Description

Exam Number/Code: 920-133

Exam name: NNCSS Baystack Switching

920-133 test is the important of Nortel certifaction. Only you pass the 920-133 exam you could have the chance to get Nortel certifaction. To help examinee, Exambible publish the Questions and Answers about 920-133 exam. And the 62 questions simulation exam are all designed by expert from Exambible. Examinees could have an enough prepare by these simulation exercises and pass the 920-133 test successfully.
Exambible also provide free 920-133 Demo, examinees can download and use before buying 920-133 Q&As, then decide if they need to purchase.

Why choose Exambible 920-133 braindumps

  • Quality and Value for the 920-133 Exam
  • 100% Guarantee to Pass Your 920-133 Exam
  • Downloadable, Interactive 920-133 Testing engines
  • Verified Answers Researched by Industry Experts
  • Drag and Drop questions as experienced in the Actual Exams
  • Practice Test Questions accompanied by exhibits
  • Our Practice Test Questions are backed by our 100% MONEY BACK GUARANTEE.

Exambible 920-133 Exam Features

  • Quality and Value for the 920-133 ExamExambible Practice Exams for Nortel 920-133 are written to the highest standards of technical accuracy, using only certified subject matter experts and published authors for development.
  • 100% Guarantee to Pass Your 920-133 ExamIf you prepare for the exam using our Exambible testing engine, we guarantee your success in the first attempt. If you do not pass the NCSS 920-133 exam (ProCurve Secure WAN) on your first attempt we will give you a FULL REFUND of your purchasing fee AND send you another same value product for free.
  • Nortel 920-133 Downloadable, Printable Exams (in PDF format)Our Exam 920-133 Preparation Material provides you everything you will need to take your 920-133 Exam. The 920-133 Exam details are researched and produced by Professional Certification Experts who are constantly using industry experience to produce precise, and logical. You may get questions from different web sites or books, but logic is the key. Our Product will help you not only pass in the first try, but also save your valuable time.
  • 920-133 Downloadable, Interactive Testing enginesWe are all well aware that a major problem in the IT industry is that there is a lack of quality study materials. Our Exam Preparation Material provides you everything you will need to take a certification examination. Like actual certification exams, our Practice Tests are in multiple-choice (MCQs) Our Nortel 920-133 Exam will provide you with exam questions with verified answers that reflect the actual exam. These questions and answers provide you with the experience of taking the actual test. High quality and Value for the 920-133 Exam:100% Guarantee to Pass Your NCSS exam and get your NCSS Certification.

Nortel NCSS 920-133 Web Demo

This webdemo is just a demo data, only for reference and learning, there is no other purposes

1. A BayStack 450-24T switch will be added to an existing stack of two BayStack 470-24T switches. The software Release running on the BayStack 450-24T switch is compatible with the software Release running on the BayStack 470-24T switches. To complete the stack creation successfully, which two configuration changes are necessary? (Choose two.)
A. Set the Unit Select switch on the BayStack 450-24T to the "Off" position.
B. Set the Unit Select switch on the BayStack 450-24T to "Base" ("On" position).
C. Set the Stack Mode for all BayStack 470-24T switches to Hybrid and then reset the stack.
D. Cable the BayStack 450-24T switch into the stack, power off all units, and then power up the stack.
E. Set the Stack Mode for the Base BayStack 470-24T switch to Hybrid and leave the other BayStack 470-24T switch as Pure.
Answer: AC


2.You are configuring a BayStack 470-48T switch for QoS and it is necessary to implement a meter as follows:
Limit bandwidth utilization to 20 Mbps.
Drop all traffic that exceeds the 20 Mbps threshold.
How do you ensure that traffic that exceeds the 20 Mbps threshold is dropped?
A. When adding the meter to the policy, set Out-of-Profile Action to Drop_Traffic .
B. When defining the Committed Burst Size of the meter, set Maximum Burst Size to 0 kbps .
C. When adding the meter to the interface group, set Threshold-Exceeded-Traffic to Drop .
D. When defining the Committed Burst Size of the meter, set Maximum Burst Size to 0 kbps and Duration to 0 seconds .
Answer: A

3. Click the exhibit button.
Given the following BayStack 325-24T switch configuration:
VLAN 10 is a port-based VLAN.
Port 1 is an untagged member of VLAN 10.
Port 5 is a tagged member of VLAN 10.
The device on Port 1 transmits an untagged frame to the device on Port 5. How will an untagged frame be treated when it reaches Port 5 on this switch?
A. It will be discarded when it is received.
B. It will be placed in a hardware-based queue based on Priority 6, it will be tagged, and transmitted out Port 5 with Priority 2.
C. It will be placed in a hardware-based queue based on Priority 6, it will be tagged, and transmitted out Port 5 with Priority 6.
D. It will be placed in a hardware-based queue based on Priority 2, it will be tagged, and transmitted out Port 5 with Priority 2.
Answer: C

4. Given the following information:
A customer has a stack of four BayStack BPS switches configured in pure mode and functioning properly.
Two BayStack 450-24T switches are added to the stack to increase its capacity and the BayStack BPS stack operation mode is changed to hybrid.
After rebooting the stack, it appears to be functioning properly but, all VLAN configurations have been lost.
What is the most likely cause of this issue and which action should you take to resolve it?
A. A BayStack 450-24T has incorrectly been assigned as the base unit. Define a BayStack BPS as the base unit and power cycle the stack to resolve the issue.
B. The Interoperability Software Version Number (ISVN) of the BayStack 450-24T software does NOT match the ISVN of the BayStack BPS software. Upgrade the BayStack 450-24T software to resolve the issue.
C. A hybrid stack only supports 64 VLANs. If more are defined on a pure BayStack BPS stack, when you change to hybrid mode you will lose all the VLANs. A maximum of 64 VLANs can be re-entered to resolve the issue.
D. When changing from a pure to a hybrid stack, the VLAN configuration will always be lost. Before changing to hybrid mode, the configuration file must be downloaded to a TFTP server, and then uploaded after changing to hybrid mode.
Answer: C

5. On a BayStack 470 switch you need to disable Internet Group Management Protocol (IGMP) snooping for a customer's VLAN (100). Using the Console Interface (CI) Menus, how should you accomplish this task?
A. From the VLAN configuration screen disable IGMP proxy for VLAN 100.
B. From the VLAN configuration screen disable IGMP snooping for VLAN 100.
C. From the VLAN configuration screen, configure the VLAN setup of port 100.
D. From the Switch configuration screen choose IGMP configuration and disable IGMP snooping for VLAN 100.
Answer: B

6. You have installed a new BayStack 460-24T switch into a customer's network and are using the QoS Wizard to configure the QoS settings for various IP traffic flows. Which two IP applications can you directly choose in the QoS Wizard to prioritize inbound frames based on traffic type? (Choose two.)
A. E-mail (SMTP)
B. File Transfer (FTP)
C. Multicasting (IGMP)
D. Trivial File Transfer (TFTP)
E. Network Management (SNMP)
Answer: AB

7. What is required to apply traffic shaping to an uplink connection from a BayStack 470-48T switch to the Passport 8600 using the Web-based Management System Interface?
A. a Media Dependent Adapter (MDA)
B. NO additional equipment is required
C. a Gigabit Interface Connector (GBIC)
D. a mini Gigabit Interface Connector (GBIC)
Answer: C

8. Given the following information:
A BayStack 460-24T-PWR switch is being installed.
The switch will be fully populated with all devices requiring Power over Ethernet (PoE).
The switch has been connected to both internal and external power sources.
The switch will be configured through web-based management.
Once you access the BayStack 460 via the BS460_24T_PWR(config)#poe poe-dc-source command, which configuration will provide the most power to supply PoE to the connected devices?
A. nes - Set DC power source from NES
B. rpsu - Set DC power source from the rpsu
C. baystack10 - Set DC power source from BayStack 10
D. unit - Set power pairs of another unit in a stack
Answer: A

Exambible materials do not contain actual questions and answers from Microsoft's Certification Exams.